Available tendons   26 WR 32 WR 36 WR 40 WR 47 WR 32 WS 36 WS
Bonded bar tendon QR-plate anchorage
with additional reinforcement
   
  QR-plate anchorage
without additional reinforcement
N    
  Rectangular solid plate anchorage
with additional reinforcement
  Rectangular solid plate anchorage
without additional reinforcement
   
  Square solid plate anchorage
without additional reinforcement
   
Unbonded and external bar tendon Rectangular solid plate anchorage
with additional reinforcement
  Square solid plate anchorage
without additional reinforcement
   
Bar designation     Threadbar Plain bar
    26 WR 32 WR 36 WR 40 WR 47 WR 32 WS 36 WS
Domed anchor nut length mm 75 90 100 115 135 46 60
width across flat mm 50 60 65 70 80 55 65
Coupler (standard) length mm 170 200 210 245 270 110 160
outside diamter mm 50 60 68 70 83 60 68
Square solid plate width mm 150 180 200 220 260 - -
length mm 150 180 200 220 260 - -
thickness mm 35 40 45 45 50 - -
Rectangular solid plate
(unbonded and bonded)
width mm 130 140 150 160 - 140 150
length mm 150 180 200 250 - 180 220
thickness mm 35 40 50 60 - 40 50
QR-plate width mm 120 140 160 180 - - -
length mm 130 165 180 195 - - -
thickness mm 30 35 40 45 - - -
Corrugated duct internal diameter mm 38 44 51 55 65 44 51
outside diameter mm 43 49 56 60 70 49 56
Minimum bar protrusion   mm 80 90 100 115 125 50 65
Rectangular solid plate
(bonded)
width mm 120 140 160 180 - - -
length mm 130 165 180 195 - - -
thickness mm 30 35 40 45 - - -
Bar designation Threadbar Plain bar
26 WR 32 WR 36 WR 40 WR 47 WR 32 WS 36 WS
60 Mp x        
110 Mp x x x x   x
200 Mp         x    
1 stressing force limited to 625 kN max.